Summary for Test 2021-05-05-30-3
Test performed: ASTM D624-00-re12Project Information
| Project Identifiers | Project ID: 215063 DEA: 032F5704 EFIS: 0300020615 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA-80-46.3/63.5 |
| Award Date | 09/23/2020 |
| Closeout Date | 08/11/2023 |
| Work Description | Replace 4 Bridges (OC) on Highway 80 from Crystal Springs to Cisco Grove (Baxter, Drum Forebay) |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/16/2020) |
Sample Information
| Sample Taken Date | 05/05/2021 | Sample Unique Key | 30 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/27/2021 | Sample type | Quality Assurance |
| A brief description of the sample | Bearing Pad | The quantity of what the sample constitutes | 9 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Mike |
| Last name of sampler or witnessed by | Spellman | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | D S Brown | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM1 - Elastomeric Bearing Pad | Mfg. Lot Number(s) | 4001799-3A |
|---|---|---|---|
| Material/Compound/Elastomer ID | NA | Samples Representing | 9 |
| Description (size) | 1.150 x 12 x 12 | Comments | |
| Description (Number of Shims) | 2 | Type of Bearing Pad | Steel |
| Description (Thickness of Shims) | 14 gage | Manufacturer(s) | D S Brown |
| Batch Number | NA |
Test Details
DIME Sample ID: 2021-05-05-30
DIME Test ID: 2021-05-05-30-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2021-06-03
Test Results
Number of specimens tested: 3
Input Type: Measured
Tester's full name: bewing
Date of test: 05/27/2021
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.083
Sample 1 Tear Strength: 251.2
Sample 2 Median Thickness: 0.082
Sample 2 Tear Strength: 252.9
Sample 3 Median Thickness: 0.082
Sample 3 Tear Strength: 249.2
UTM: 2kip
Median of the Tear Strength Values: 251.2 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Sample 3
Source: Bluehill Data Point File
Test graph for Sample 2
Source: Bluehill Data Point File
Test graph for Sample 1
Test was verified on 6/3/2021 ✔