Summary for Test 2021-04-12-58-3

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 212501
DEA: 022E4804
EFIS: 0200000586
DIST-CO-RTE-PM02-SIS-96,263-103.1/103.6,56.8/57.2
Award Date12/14/2018
Closeout Date12/01/2021
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 8 MILES NORTH OF YREKA ON ROUTE 96 FROM 0.5 MILE WEST TO 0.2 MILE EAST OF ROUTE 263 AND ON ROUTE 263 FROM 0.3 MILE NORTH OF SHASTA RIVER BRIDGE #02-0014 TO ROUTE 96
QA Service Level1 (Verified on 06/06/2017)

Sample Information

Sample Taken Date04/12/2021 Sample Unique Key58
Date that the sample was received by the laboratory/organization performing the testing04/12/2021 Sample typeDepartment Acceptance
A brief description of the sample3/8-inch RAP (Combined) The quantity of what the sample constitutesProduction Start-Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byRandy
Last name of sampler or witnessed byX Title of samplerCGI
Telephone number of sampler Laboratory sample identificationD78772B
Linked DIME Sample ID The fabricator/manufacturer/facility nameJF Shea Construction, Fawndale Rock and Asphalt, Redding, CA
Transportation Laboratory (TL) Number897284 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceFawndale Rock and Asphalt, Redding, CA
Aggregate Size3/8-inch Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-12-58
DIME Test ID: 2021-04-12-58-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-05-21

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 04/13/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7336.6 grams
Mass of oven-dry sample in air for Sample 1: 1597.3 grams
Mass of container filled with the sample and water for Sample 1: 8303.2 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.533
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/21/2021 ✔