Summary for Test 2015-07-07-4-1
Test performed: CTM 521-November 2014Project Information
| Project Identifiers | Project ID: 209356 DEA: 07278204 EFIS: 0700000538 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10,110,118,134,210,710-Var |
| Award Date | 04/18/2014 |
| Closeout Date | 07/13/2016 |
| Work Description | UPGRADE CURB RAMPS. |
| Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 10/31/2014) |
Sample Information
| Sample Taken Date | 07/07/2015 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/10/2015 | Sample type | Quality Assurance |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Cardiel |
| Last name of sampler or witnessed by | Bugarin | Title of sampler | Structure Representative |
| Telephone number of sampler | Unknown | Laboratory sample identification | 912-01F |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Robertsons |
| Transportation Laboratory (TL) Number | 10001F | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | 53 1748 | Structure name | Central Ave OC Curb Ramp on Bridge |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SC590B38 |
|---|---|---|---|
| The truck number from where the sample was collected | 4813181 | The batch plant ticket number from where the sample was collected | 9700275 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Plant |
| A detailed description of where the material sample was collected | Truck | Where the material sample would have been placed if not sampled | South East corner Curb Ramp |
| From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-07-07-4
DIME Test ID: 2015-07-07-4-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-07-21
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 07/21/2015
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 85480 lb
Maximum load on cylinder 2: 80840 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 14 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3023.7 psi
Compressive strength of cylinder 2: 2859.6 psi
Compressive strength (to nearest 10 psi): 2940 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/21/2015 ✔