Summary for Test 2015-06-23-2-1
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 5266 DEA: 08448404 EFIS: 0800000712 COOP: 081488A1 |
---|---|
DIST-CO-RTE-PM | 08-RIV-91-15.6/21.6 |
Award Date | 02/10/2012 |
Closeout Date | 07/27/2023 |
Work Description | CONSTRUCT HOV LANES AND WIDEN BRIDGES. |
Location Description | RIVERSIDE COUNTY IN RIVERSIDE FROM ADAMS STREET TO THE ROUTE 60/215 SEPARATION |
QA Service Level | 1 (Verified on 04/27/2012) |
Sample Information
Sample Taken Date | 06/23/2015 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/25/2015 |
Sample type | Quality Control | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | D | Last name of sampler or witnessed by | P |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 825-59 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | JOB | Transportation Laboratory (TL) Number | 099059 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | ADAMS ST TO 60 AND 215 SEP |
Structure name | IVY ST OC REPLACE BENT COLUMN RIGHT OR EAST |
Material Information
Material Type | Concrete | The concrete mix design number | SC590B38 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | NP |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-06-23-2
DIME Test ID: 2015-06-23-2-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-07-21
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 07/21/2015
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6 in
Maximum load on cylinder 1: 119840 lb
Maximum load on cylinder 2: 117600 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 4224.2 psi
Compressive strength of cylinder 2: 4159.9 psi
Compressive strength (to nearest 10 psi): 4190 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/21/2015 ✔