Summary for Test 2021-04-01-26-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 212914
DEA: 031E0604
EFIS: 0312000068
DIST-CO-RTE-PM03-YUB-70-15.5/16.5
Award Date07/31/2019
Closeout Date08/30/2023
Work DescriptionSIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055.
Location DescriptionNEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019.
QA Service Level1 (Verified on 08/22/2019)

Sample Information

Sample Taken Date04/01/2021 Sample Unique Key26
Date that the sample was received by the laboratory/organization performing the testing04/01/2021 Sample typeVerification
A brief description of the sampleRAP minus 1/2" The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byTeichert Personnel (SAMPLER)
Last name of sampler or witnessed by Brad McKeehan (WITNESS) Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationJMF21-020A
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert-Hallwood Drum Plant
Transportation Laboratory (TL) NumberC706328 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameNot Applicable
Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceTeichert Hallwood, RAP Bin 1
Aggregate Size Aggregate Source
RAP StockpileStatic Stockpile Size (tons)Unknown
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-01-26
DIME Test ID: 2021-04-01-26-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-05-05

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Mario Munoz
Date of test: 01/13/2021
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.55 %
General comments (publicly viewable) (Max 1000 characters): JMF21-020A.

Test was verified on 5/5/2021 ✔