Summary for Test 2021-04-01-24-2
Test performed: AASHTO T96-02r10Project Information
Project Identifiers | Project ID: 212914 DEA: 031E0604 EFIS: 0312000068 |
---|---|
DIST-CO-RTE-PM | 03-YUB-70-15.5/16.5 |
Award Date | 07/31/2019 |
Closeout Date | 08/30/2023 |
Work Description | SIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055. |
Location Description | NEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019. |
QA Service Level | 1 (Verified on 08/22/2019) |
Sample Information
Sample Taken Date | 04/01/2021 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/01/2021 |
Sample type | Verification | A brief description of the sample | 3/4" (Nominal Sized( Untreated Virgin Aggregate |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Teichert Personnel (SAMPLER) | Last name of sampler or witnessed by | Brad McKeehan (WITNESS) |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | JMF21-020A | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Teichert-Hallwood Drum Plant | Transportation Laboratory (TL) Number | C706328 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Not Applicable |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-58-0006::HALLWOOD PLANT |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Cold Feed |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Not Applicable | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-04-01-24
DIME Test ID: 2021-04-01-24-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2021-05-04
Test Results
Input Type: Calculated
Tester's full name: Julian Gonzales
Date of test: 04/21/2021
Grading designation: C
Percent loss after 100 revolutions: 4 %
Percent loss after 500 revolutions: 18 %
General comments (publicly viewable) (Max 1000 characters): JMF21-020A. Julian Gonzales
Test was verified on 5/4/2021 ✔