Summary for Test 2021-04-21-18-4

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 209520
DEA: 06470904
EFIS: 0600000973
COOP: 061529
DIST-CO-RTE-PM06-MAD-99-R7.5/15.1
Award Date03/14/2019
Closeout Date05/11/2023
Work DescriptionWIDEN FREEWAY FROM 4 LANES TO 6 LANES.
Location DescriptionMADERA COUNTY IN AND NEAR MADERA FROM AVENUE 12 OVERCROSSING TO 0.9 MILE NORTH OF AVENUE 17 OVERCROSSING
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date04/21/2021 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing04/28/2021 Sample typeDepartment Acceptance
A brief description of the sampleAsphalt Binder The quantity of what the sample constitutes1 of 1 can
From where was the sample collectedManufacturer First name of sampler or witnessed byG
Last name of sampler or witnessed bydih Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Madera
Transportation Laboratory (TL) Numberc816159 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number10
Sublot number3 Tank number
Time of sample HMA SupplierVulcan Madera
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade TypeNot set Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2021-04-21-18
DIME Test ID: 2021-04-21-18-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-05-05

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 05/04/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 20.998 kPa
Phase Angle (δ) (for the 10 cycles): 72.4 degree
Complex Modulus (G*) (for the 10 measurements): 2099.753 kPa
Test Temperature (Specimen 1): 34.0 C
(G*) x sin(δ)=: 2001 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 5/5/2021 ✔