Summary for Test 2021-04-23-10-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout Date06/05/2024
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date04/23/2021 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/29/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15 No LAS
The quantity of what the sample constitutes4 Bags Of Combined Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byAAA Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0244A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number105973 A detailed description of where the material sample was collectedBelt Cut at All American Corona Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-23-10
DIME Test ID: 2021-04-23-10-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-05-04

Test Results


Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 05/03/2021
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 969.9 grams
Mass of the pycnometer with water (B): 653.2 grams
Mass of the oven dried sample (before pycnometer) (A): 493.4 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 493.4 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.692
Bulk specific gravity (SSD Basis): 2.728
Apparent specific gravity: 2.792
Absorption: 1.3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/4/2021