Summary for Test 2021-04-05-24-5
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 04/05/2021 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/07/2021 |
Sample type | Quality Control | A brief description of the sample | Asphalt Binder PG 64-16 |
The quantity of what the sample constitutes | 1 of 2 split sample | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | PAT Ops | Last name of sampler or witnessed by | PAT Ops |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 6416-040521 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Valero Pittsburg | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | 150 | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Valero-NuStar PAT - Pittsburg CA | Multigrade | Yes |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-04-05-24
DIME Test ID: 2021-04-05-24-5
Testing Lab: Valero-NuStar PAT - Pittsburg
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-04-30
Test Results
Phase: PAV residue
Input Type: Calculated
Tester's full name: APART
Date of test: 04/09/2021
Test Plate Diameter: 8 mm
Phase Angle (δ) (for the 10 cycles): 50.4 degree
(G*) x sin(δ)=: 2060 kPa
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/30/2021 ✔