Summary for Test 2021-04-08-34-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 215734 DEA: 024H0104 EFIS: 0218000068 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-78.3/90.3 |
| Award Date | 01/29/2025 |
| Closeout Date | Not set |
| Work Description | REPLACE AC SURFACING, PLACE HMA AND THERMOPLASTIC TRAFFIC STRIPING. |
| Location Description | PLUMAS COUNTY NEAR PORTOLA FROM 0.4 MILE WEST OF BIG GRIZZLY CREEK BRIDGE TO 0.8 MILE WEST OF SUMMIT SCHOOL DRIVE |
| QA Service Level | 1 (Verified on 07/08/2021) |
Sample Information
| Sample Taken Date | 04/08/2021 | Sample Unique Key | 34 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/09/2021 | Sample type | Preliminary |
| A brief description of the sample | Soil | The quantity of what the sample constitutes | Culvert Recommendation |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Brian |
| Last name of sampler or witnessed by | Steiner | Title of sampler | TE |
| Telephone number of sampler | Laboratory sample identification | D78763 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | None | |
| Transportation Laboratory (TL) Number | 824587 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-PLU-70-81.23 Outlet of culvert Depth 4-8in | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2021-04-08-34
DIME Test ID: 2021-04-08-34-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2021-05-20
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 04/22/2021
Minimum soil resistance of the lab measurement: 8750 Ohms
Soil sample temperature: 20 C
Soil box constant: 1
pH of soil: 7.06
Minimum soil resistance corrected to 15.5: 9734.38 Ohm-cm
Minimum soil resistivity at 15.5: 9734 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/20/2021 ✔