Summary for Test 2021-03-18-23-6
Test performed: AASHTO T350-19Project Information
| Project Identifiers | Project ID: 55555 DEA: AMRL EFIS: AMRL |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for AASHTO Materials Reference Laboratory (AMRL). |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/18/2021 | Sample Unique Key | 23 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/26/2021 | Sample type | Proficiency |
| A brief description of the sample | 264(B) PSP PERFORMANCE GRADED | The quantity of what the sample constitutes | 1 of 1 can |
| From where was the sample collected | Other | First name of sampler or witnessed by | AASHTO resource |
| Last name of sampler or witnessed by | AASHTO resource | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AASHTO resource PSP | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 70-22 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | AASHTO Resource - Frederick MD | Multigrade | No |
| Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2021-03-18-23
DIME Test ID: 2021-03-18-23-6
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T350-19: Multiple Stress Creep Recovery (MSCR) Test of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Multiple Stress Creep Recovery)
Test Release Date: 2021-05-18
Test Results
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 04/27/2021
PG test temperature: 70.0 C
Average percent recovery at 0.1 kPa: 5.0200 %
Average percent recovery at 3.2 kPa: 0.0000 %
Nonrecoverable creep compliance: 3.2862
Nonrecoverable creep compliance: 3.8926
Percent difference between nonrecoverable creep compliance at 0.1 kPa and 3.2 kPa: 18.4500 %
General comments (publicly viewable) (Max 1000 characters): MSCR - A1
Test was verified on 5/18/2021 ✔