Summary for Test 2021-04-07-17-5

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 214336
DEA: 07302404
EFIS: 0713000488
DIST-CO-RTE-PM07-VEN-101-37/40
Award Date11/17/2020
Closeout Date09/24/2024
Work DescriptionPADRE JUAN REHAB
Location DescriptionVEN 101
QA Service Level1 (Verified on 02/26/2021)

Sample Information

Sample Taken Date04/07/2021 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing04/13/2021 Sample typeVerification
A brief description of the sampleJMF 3/4" HMA-A-SP R25 No LAS The quantity of what the sample constitutes4 Bags of Coldfeed, 2 Bags of RAP
From where was the sample collectedManufacturer First name of sampler or witnessed byKevin
Last name of sampler or witnessed byHopkins Title of sampler
Telephone number of sampler Laboratory sample identification0217A-21
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Santa Paula
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046::BIG ROCK CREEK- GRANITE
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R25 The fabricator/manufacturer designation for the sample
The plant number2265 A detailed description of where the material sample was collectedBelt Cut at Granite Santa Paula Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-07-17
DIME Test ID: 2021-04-07-17-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2021-04-27

Test Results


Input Type: Measured
Tester's full name: Sebastian Ferrer
Date of test: 04/23/2021
Grading designation: B
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4691 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3551 grams
Percent loss after 100 revolutions: 6 %
Percent loss after 500 revolutions: 29 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/27/2021 ✔