Summary for Test 2021-04-12-17-1

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 214852
DEA: 09380904
EFIS: 0919000059
DIST-CO-RTE-PM09-INY,MNO-178,6-42.9/48.6,26.5/32.3
Award Date05/07/2020
Closeout Date08/10/2021
Work DescriptionPLACE HMA OVER EXISTING ASPHALT CONCRETE PAVEMENT.
Location DescriptionINYO AND MONO COUNTIES ON ROUTE 178 FROM ROUTE 127 TO 5.7 MILES EAST OF ROUTE 127 AND ON ROUTE 6 FROM 0.8 MILE NORTH OF ROUTE 120 TO THE NEVADA STATE LINE
QA Service Level1 (Verified on 08/04/2020)

Sample Information

Sample Taken Date04/12/2021 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/12/2021
Sample typeQuality Control A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes200tons From where was the sample collectedSupplier
First name of sampler or witnessed byDan Last name of sampler or witnessed byVirkler
Title of sampler Telephone number of sampler7027362059
Laboratory sample identificationZ3227035 Linked DIME Sample ID
The fabricator/manufacturer/facility nameErgon Las Vegas Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierErgon Asphalt & Emulsions Incorporated - Las Vegas NV MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-12-17
DIME Test ID: 2021-04-12-17-1
Testing Lab: Ergon Asphalt & Emulsions
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-04-14

Test Results


Phase: Original binder
Input Type: Calculated
Tester's full name: Dan Virkler
Date of test: 04/12/2021
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 87.7 degree
Dynamic Shear, G*/sin(δ): 1.12 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/14/2021