Summary for Test 2021-03-29-1-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 214702 DEA: 030F2864 EFIS: 0320000123 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-99-7.92 / 8.4 |
| Award Date | 06/24/2020 |
| Closeout Date | 11/28/2023 |
| Work Description | Remove and replace Consumnes River and Consumnes River Overflow bridge |
| Location Description | Sacramento County |
| QA Service Level | 1 (Verified on 04/20/2020) |
Sample Information
| Sample Taken Date | 03/29/2021 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/29/2021 |
| Sample type | Quality Assurance | A brief description of the sample | #8 welded hoops (6'-2" dia) |
| The quantity of what the sample constitutes | 656 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | Cattabiani |
| Title of sampler | AMR | Telephone number of sampler | 2016746612 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMC Rebar Etiwanda | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4106041 |
| Hoop Manufacturer Lot Number(s) | Lots 47 - 51 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #8 |
| Diameter of Hoop | 6'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel Arizona |
| Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2021-03-29-1
DIME Test ID: 2021-03-29-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-04-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 04/12/2021
UTM: 400kip
Temperature: 72 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 51 | 8/25mm | 0.79 | 78876.53 | 99844 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 4/12/2021 ✔