Summary for Test 2021-03-01-35-2

Test performed: ASTM C39-18

Project Information

Project IdentifiersProject ID: 212571
DEA: 051F79A4
EFIS: 0514000061
DIST-CO-RTE-PM05-SB-101-55.9/R56.2
Award Date09/13/2022
Closeout Date07/02/2026
Work DescriptionNojoqui Creek Bridge (51-0018 L/R) widening and rail replacement.
Location DescriptionIN SANTA BARBARA COUNTY NEAR BUELLTON AT NOJOQUI CREEK BRIDGE (BR #51-0018 L/R)
QA Service Level1 (Verified on 02/20/2020)

Sample Information

Sample Taken Date03/01/2021 Sample Unique Key35
Date that the sample was received by the laboratory/organization performing the testing03/02/2021 Sample typeQuality Control
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes11 CY
From where was the sample collectedFabricator First name of sampler or witnessed byStephen
Last name of sampler or witnessed byHaynes Title of samplerQC Inspector Technician
Telephone number of sampler9253317125 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameKIE-CON, INC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberK3050-300CPx
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected109610
Concrete batch plant The fabricator/manufacturer designation for the sample20-096 3/1/21
A detailed description of where the material sample was collectedConcrete sample from wheelbarrow Where the material sample would have been placed if not sampledRectangular Girder
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-03-01-35
DIME Test ID: 2021-03-01-35-2
Testing Lab: Kie-Con, Incorporated - Antioch
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-03-29

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Stephen Haynes
Date of test: 03/29/2021
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Capped in accordance with?: ASTM C617/CTM521
Maximum load on cylinder 1: 245900 lb
Maximum load on cylinder 2: 234460 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 673 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 8500 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/29/2021 ✔