Summary for Test 2021-01-12-24-1
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 214293 DEA: 060S4604 EFIS: 0615000038 |
---|---|
DIST-CO-RTE-PM | 06-FRE-99-R0.9/R5.0 |
Award Date | 12/05/2019 |
Closeout Date | 05/11/2023 |
Work Description | REPLACE CONCRETE AND ASPHALT PAVEMENT. |
Location Description | FRESNO COUNTY IN AND NEAR KINGSBURG AND SELMA FROM ROUTE 99/201 SEPARATION TO 0.3 MILE SOUTH OF SECOND STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 08/05/2019) |
Sample Information
Sample Taken Date | 01/12/2021 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/22/2021 |
Sample type | Department Acceptance | A brief description of the sample | Project Sample |
The quantity of what the sample constitutes | 1 of 5 | From where was the sample collected | Source |
First name of sampler or witnessed by | G. | Last name of sampler or witnessed by | DITT |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMI FRESNO | Transportation Laboratory (TL) Number | C040299 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-10 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-01-12-24
DIME Test ID: 2021-01-12-24-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-03-30
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 02/25/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.248 kPa
Phase Angle (δ) (for the 10 cycles): 84.2 degree
Complex Modulus (G*) (for the 10 measurements): 2.066 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 2.08 kPa
General comments (publicly viewable) (Max 1000 characters): MSCR Study ORIG
Test was verified on 3/30/2021 ✔