Summary for Test 2021-03-23-14-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214795
DEA: 030H3424
EFIS: 0317000153
DIST-CO-RTE-PM03-SAC-99-22.6
Award Date11/13/2020
Closeout Date03/03/2022
Work DescriptionREPLACE BRIDGE DECK WITH PRESTRESSED CONCRETE BOX GIRDER.
Location DescriptionSACRAMENTO COUNTY IN SACRAMENTO AT 21ST AVENUE UNDERCROSSING
QA Service Level1 (Verified on 03/12/2020)

Sample Information

Sample Taken Date03/23/2021 Sample Unique Key14
Date that the sample was received by the laboratory/organization performing the testing03/23/2021 Sample typeQuality Assurance
A brief description of the sampleGalvanized rebar with welded wire mesh The quantity of what the sample constitutes8 of 192
From where was the sample collectedFabricator First name of sampler or witnessed byBrandon
Last name of sampler or witnessed byMiller Title of samplerSR
Telephone number of sampler9165056839 Laboratory sample identification001
Linked DIME Sample ID The fabricator/manufacturer/facility nameConfab Lathrop - KRC Vernalis
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name21st Avenue UC
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateService Rebar Heat Number(s)2012525
Hoop Manufacturer Lot Number(s)1 and 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop0'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerVinton Steel
Welding CompanyPacific Galvanizing Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2021-03-23-14
DIME Test ID: 2021-03-23-14-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-03-29

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 03/29/2021
UTM: 75kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1115/16mm0.3129630.0095581Broke at Wirefsaylor

General comments (publicly viewable) (Max 1000 characters): Broke at Wire
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 3/29/2021 ✔