Summary for Test 2020-12-03-14-1
Test performed: CTM 214-August 2010Project Information
| Project Identifiers | Project ID: 212657 DEA: 024G5004 EFIS: 0214000031 |
|---|---|
| DIST-CO-RTE-PM | 02-TRI-299-1.9-2.3 |
| Award Date | 10/01/2019 |
| Closeout Date | 11/24/2021 |
| Work Description | VIADUCT WIDENING |
| Location Description | TRINITY COUNTY NEAR SALYER FROM 0.1 MILE EAST TO 0.6 MILE EAST OF WHITE HOUSE GULCH ROAD |
| QA Service Level | 1 (Verified on 09/04/2018) |
Sample Information
| Sample Taken Date | 12/03/2020 | Sample Unique Key | 14 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/03/2020 | Sample type | Per Request |
| A brief description of the sample | Fine PCC Aggregate | The quantity of what the sample constitutes | Unknown Quantity |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Colt |
| Last name of sampler or witnessed by | Sweeny | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | D78703B | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Eureka Ready Mix | |
| Transportation Laboratory (TL) Number | 897722 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unkown |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-12-03-14
DIME Test ID: 2020-12-03-14-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2021-03-24
Test Results
What size aggregate is being tested?: Fine Aggregate
Input Type: Calculated
Tester's full name: BN/JH
Date of test: 03/24/2021
Percentage Loss of material retained on #8 sieve: no data
Percentage Loss of material retained on #16 sieve: no data
Percentage Loss of material retained on #30 sieve: no data
Percentage Loss of material retained on #50 sieve: no data
Percentage Loss of material retained on #100 sieve: no data
Weighted Average Percent Loss of Fine Aggregate: 5.0 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/24/2021 ✔