Summary for Test 2020-10-25-8-2

Test performed: AASHTO T275-07r12
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date10/25/2020 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing01/07/2021 Sample typeVerification
A brief description of the sample3/4" HMA - A LL (Surface) w/15% RAP The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byJ. Buscheck (WITNESS)
Last name of sampler or witnessed byTeichert Personnel (SAMPLER) Title of sampler
Telephone number of sampler Laboratory sample identificationJMF21-002
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Perkins Batch Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-10-25-8
DIME Test ID: 2020-10-25-8-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2021-03-22

Test Results


Number of tests: 3
What test procedure is performed?: Method A
Input Type: Calculated
Tester's full name: Ben Dreher
Date of test: 03/04/2021
123

2.497

2.501

2.496

1.498
General comments (publicly viewable) (Max 1000 characters): JMF21-002.

Test was verified on 3/22/2021

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.