Summary for Test 2021-02-19-10-2

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 212085
DEA: 07296604
EFIS: 0713000057
DIST-CO-RTE-PM07-LA-10-14.0/19.0
Award Date06/04/2018
Closeout Date05/04/2023
Work DescriptionPAINT AND REHABILITATE BRIDGE - (STRAIN (PAINT AND INSTALL CATWALK)
Location DescriptionIN THE CITY OF LOS ANGELES, AT SANTA MONICA VIADUCT (BR. NO. 53-1301). PAINT AND REHABILITATE BRIDGE
QA Service Level1 (Verified on 07/25/2018)

Sample Information

Sample Taken Date02/19/2021 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing02/19/2021 Sample typeVerification
A brief description of the sampleASTM F436 Bevel Washer The quantity of what the sample constitutes2000
From where was the sample collectedDistributor First name of sampler or witnessed byBrian
Last name of sampler or witnessed byMurray Title of samplerQA Inspector
Telephone number of sampler213 435 4055 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePage Industrial
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL140-048-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)JL9129 Nut Mfg. Lot Number(s)n/a
Washer Mfg. Lot Number(s)317906 Bolt Specificationn/a
Bolt Length(s)n/a Nut Specificationn/a
Washer SpecificationASTM F436 FinishHot Dipped Galvanized
Diameter/Size3/4" Bolt Mfg. Lot Number n/a
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2021-02-19-10
DIME Test ID: 2021-02-19-10-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-03-16

Test Results


Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 03/16/2021
Sample No.: 1B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 317906
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: W
Size: .75 in
Bolt Length: no data
Measurement Average: 5.05 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/16/2021 ✔