Summary for Test 2021-02-05-26-4
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/05/2021 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/12/2021 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 3/8" crushed rock APP |
The quantity of what the sample constitutes | about 140 lb | From where was the sample collected | Source |
First name of sampler or witnessed by | Jordan Baker | Last name of sampler or witnessed by | Jordan Baker |
Title of sampler | QC Manager | Telephone number of sampler | 530-227-0982 |
Laboratory sample identification | 21-APP-0041 | Linked DIME Sample ID | 2021-02-05-23 |
The fabricator/manufacturer/facility name | Deer Creek Rock and Asphalt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-54-0021::DEER CREEK ASPHALT |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile at plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-02-05-26
DIME Test ID: 2021-02-05-26-4
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2021-04-02
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 03/15/2021
Top sediment column reading (single primary size): 0.3 in
Cleanness value (single primary size): 91
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/2/2021 ✔