Summary for Test 2021-02-25-11-2
Test performed: AASHTO T335-09r13Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/25/2021 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/05/2021 |
Sample type | Verification | A brief description of the sample | Aggreagte |
The quantity of what the sample constitutes | 10 bags - 3 bin 3, 3, bin 2, 3 bin 1, and 1 mineral filler | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Zuri | Last name of sampler or witnessed by | Abajian |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 21-JMFPP-0030 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Syar Industries Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-49-0004::CANYON ROCK CO., INC. |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Bin | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-02-25-11
DIME Test ID: 2021-02-25-11-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2021-03-12
Test Results
Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 03/12/2021
Mass of fractured, coarse, 2 faced particles tested: 1643.5 g
Mass of questionable, coarse, 2 faced particles tested: 0 g
Mass of unfractured, coarse, 2 faced particles tested: 0 g
Mass of fractured, coarse, 1 faced particles tested: 1643.5 g
Mass of questionable, coarse, 1 faced particles tested: 0 g
Mass of unfractured, coarse, 1 faced particles tested: 0 g
Mass of fractured, fine, 1 faced particles tested: 26.3 g
Mass of questionable, fine, 1 faced particles tested: 0 g
Mass of unfractured, fine, 1 faced particles tested: 0 g
Percentage of questionable, coarse, 2 faced particles tested: 0 %
Percentage of questionable, coarse, 1 faced particles tested: 0 %
Percentage of questionable, fine, 1 faced particles tested: 0 %
Percentage of fractured, coarse, 2 faced particles tested: 100 %
Percentage of fractured, coarse, 1 faced particles tested: 100 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters): Crushed particles, coarse aggregate One fractured face and Crushed particles, coarse aggregate Two fractured faces - Method 1 Crushed particles, fine aggregate (Passing No. 4 sieve and retained on No. 8 sieve) One fractured face - Method 2
Test was verified on 3/12/2021 ✔