Summary for Test 2021-02-19-2-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 212085 DEA: 07296604 EFIS: 0713000057 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-14.0/19.0 |
Award Date | 06/04/2018 |
Closeout Date | 05/04/2023 |
Work Description | PAINT AND REHABILITATE BRIDGE - (STRAIN (PAINT AND INSTALL CATWALK) |
Location Description | IN THE CITY OF LOS ANGELES, AT SANTA MONICA VIADUCT (BR. NO. 53-1301). PAINT AND REHABILITATE BRIDGE |
QA Service Level | 1 (Verified on 07/25/2018) |
Sample Information
Sample Taken Date | 02/19/2021 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/19/2021 |
Sample type | Verification | A brief description of the sample | A325 Fastener Assembly |
The quantity of what the sample constitutes | 1500 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | QA Inspector | Telephone number of sampler | 213 435 4055 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Page Industrial | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-048-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 33631-190839 | |
Washer Mfg. Lot Number(s) | D9458 | Bolt Specification | ASTM A325TC |
Bolt Length(s) | 1 3/4" | Nut Specification | ASTM A563 |
Washer Specification | ASTM F436 | Finish | Mechanical Galvanized |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 33539-100203733 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-02-19-2
DIME Test ID: 2021-02-19-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-03-16
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 03/12/2021
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1B | 33631-190839 | 53064 | Proof Load | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 3/16/2021 ✔