Summary for Test 2021-03-01-19-2
Test performed: AASHTO T301-13Project Information
| Project Identifiers | Project ID: 55555 DEA: AMRL EFIS: AMRL |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for AASHTO Materials Reference Laboratory (AMRL). |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/01/2021 | Sample Unique Key | 19 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/08/2021 |
| Sample type | Informational | A brief description of the sample | Asphalt Binder |
| The quantity of what the sample constitutes | 1 can, Due March 25 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | OREGON COOP | Last name of sampler or witnessed by | OREGON COOP |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 311 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | US OIL REFINING CO | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | 3002 | |
| Time of sample | 23:28:00 | HMA Supplier | |
| Certified Asphalt Supplier | PNAC LLC - Fernley NV | Multigrade | Not set |
| Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-03-01-19
DIME Test ID: 2021-03-01-19-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T301-13: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Test Release Date: 2021-03-11
Test Results
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 03/11/2021
Final Reading from the testing machine (X): 4 cm
% Elongation Recovery: 80 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/11/2021 ✔