Summary for Test 2021-03-02-3-5
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 213750 DEA: 120K0224 EFIS: 1214000097 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-14.5/17.1 |
| Award Date | 03/05/2019 |
| Closeout Date | 03/13/2025 |
| Work Description | South County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS. |
| Location Description | ORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING |
| QA Service Level | 1 (Verified on 04/15/2019) |
Sample Information
| Sample Taken Date | 03/02/2021 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/05/2021 |
| Sample type | Quality Assurance | A brief description of the sample | #5 welded hoops, 2' 8" dia |
| The quantity of what the sample constitutes | 1470 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 6466327821 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L134-030-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1202019459 |
| Hoop Manufacturer Lot Number(s) | 1, 6 and 10 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #5 |
| Diameter of Hoop | 2'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor Utah |
| Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2021-03-02-3
DIME Test ID: 2021-03-02-3-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-03-08
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 03/05/2021
UTM: 400kip
Temperature: 72 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 6 | 5/16mm | 0.31 | 26695.29 | 86114 | Ok Necking | bewing |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 3/8/2021 ✔