Summary for Test 2021-01-20-28-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 215544 DEA: 024G7004 EFIS: 0214000048 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-89-14.6/15 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 07/08/2021) |
Sample Information
| Sample Taken Date | 01/20/2021 | Sample Unique Key | 28 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/20/2021 | Sample type | Preliminary |
| A brief description of the sample | Soil | The quantity of what the sample constitutes | Culvert Recommendation |
| From where was the sample collected | Source | First name of sampler or witnessed by | Colt |
| Last name of sampler or witnessed by | Sweeny | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | D78728 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Caltrans | |
| Transportation Laboratory (TL) Number | 875676 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-PLU-89-14.82, Culvert Inlet | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2021-01-20-28
DIME Test ID: 2021-01-20-28-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2021-03-08
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 01/27/2021
Minimum soil resistance of the lab measurement: 11000 Ohms
Soil sample temperature: 16.1 C
Soil box constant: 1
pH of soil: 6.22
Minimum soil resistance corrected to 15.5: 11165 Ohm-cm
Minimum soil resistivity at 15.5: 11165 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/8/2021 ✔