Summary for Test 2021-01-20-25-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 215542 DEA: 024H6604 EFIS: 0219000001 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-96-60.8/93.8 |
| Award Date | 10/12/2023 |
| Closeout Date | 03/21/2025 |
| Work Description | SIS WORKER SAFETY SHOPP |
| Location Description | SISKIYOU COUNTY AT VARIOUS LOCATIONS FROM 0.3 MILE WEST OF KLAMATH RIVER BRIDGE BR. NO. 02-0119 TO 0.8 MILE EAST OF EMPIRE CREEK |
| QA Service Level | 1 (Verified on 07/08/2021) |
Sample Information
| Sample Taken Date | 01/20/2021 | Sample Unique Key | 25 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/20/2021 |
| Sample type | Preliminary | A brief description of the sample | Soil |
| The quantity of what the sample constitutes | Culvert Recommendation | From where was the sample collected | Source |
| First name of sampler or witnessed by | Darrell | Last name of sampler or witnessed by | Valasek |
| Title of sampler | TET | Telephone number of sampler | 5302253414 |
| Laboratory sample identification | D78725 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | 897724 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-SIS-96-87.83, Stream line | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2021-01-20-25
DIME Test ID: 2021-01-20-25-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2021-03-08
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 01/26/2021
Minimum soil resistance of the lab measurement: 3950 Ohms
Soil sample temperature: 19 C
Soil box constant: 1
pH of soil: 7.10
Minimum soil resistance corrected to 15.5: 4295.63 Ohm-cm
Minimum soil resistivity at 15.5: 4296 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/8/2021 ✔