Summary for Test 2021-01-30-3-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 213746
DEA: 080Q75U4
EFIS: 0817000114
DIST-CO-RTE-PM08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2
Award Date04/18/2019
Closeout Date06/28/2022
Work DescriptionREPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS
Location DescriptionNot set
QA Service Level1 (Verified on 06/17/2019)

Sample Information

Sample Taken Date01/30/2021 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing02/02/2021 Sample typeQuality Assurance
A brief description of the sampleCONCRETE CYLINDERS The quantity of what the sample constitutes6 CYLINDERS
From where was the sample collectedJob Site First name of sampler or witnessed byPAUL
Last name of sampler or witnessed byPASTORA Title of samplerRMA
Telephone number of sampler Laboratory sample identification999-130
Linked DIME Sample ID The fabricator/manufacturer/facility nameShort Load Concrete Inc
Transportation Laboratory (TL) Number999-130 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-30-RAM
The truck number from where the sample was collectedNA The batch plant ticket number from where the sample was collected14
Concrete batch plantVOLUMETRIC TRUCK The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSITE Where the material sample would have been placed if not sampledI15 CONNECTOR ON THE 60EB FWY STA 1745 TO 1113
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-01-30-3
DIME Test ID: 2021-01-30-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-03-04

Test Results


Unit system used?: US Units
Number of specimens: 6
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 02/06/2021
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.01 in
Average diameter of cylinder 3: 6.00 in
Average diameter of cylinder 4: 5.99 in
Average diameter of cylinder 5: 6.02 in
Average diameter of cylinder 6: 6.00 in
Maximum load on cylinder 1: 25290 lb
Maximum load on cylinder 2: 23000 lb
Maximum load on cylinder 3: 27730 lb
Maximum load on cylinder 4: 26710 lb
Maximum load on cylinder 5: 26480 lb
Maximum load on cylinder 6: 27290 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 4
Type of fracture pattern of cylinder 4: 2
Type of fracture pattern of cylinder 5: 2
Type of fracture pattern of cylinder 6: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Correction factor for cylinder 4: 1.00
Correction factor for cylinder 5: 1.00
Correction factor for cylinder 6: 1.00
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Cross sectional area of cylinder 3: 28.27 in^2
Cross sectional area of cylinder 4: 28.18 in^2
Cross sectional area of cylinder 5: 28.46 in^2
Cross sectional area of cylinder 6: 28.27 in^2
Compressive strength of cylinder 1: 894.6 psi
Compressive strength of cylinder 2: 810.7 psi
Compressive strength of cylinder 3: 980.9 psi
Compressive strength of cylinder 4: 947.8 psi
Compressive strength of cylinder 5: 930.4 psi
Compressive strength of cylinder 6: 965.3 psi
Compressive strength (to nearest 10 psi): 920 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/4/2021 ✔