Summary for Test 2021-02-09-16-5
Test performed: ASTM E18-15Project Information
| Project Identifiers | Project ID: 215014 DEA: 101C9404 EFIS: 1016000020 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-5-26.4/27.0 |
| Award Date | 11/03/2020 |
| Closeout Date | 03/03/2022 |
| Work Description | BRIDGE REHABILITATION |
| Location Description | ON STATE HIGHWAY IN SAN JOAQUIN COUNTY IN STOCKTON FROM 0.3 MILE NORTH OF ROUTE 5/4 SEPARATION TO PERSHING AVENUE |
| QA Service Level | 1 (Verified on 06/03/2020) |
Sample Information
| Sample Taken Date | 02/09/2021 | Sample Unique Key | 16 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/12/2021 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM F436 washers 1" diam. |
| The quantity of what the sample constitutes | 174 washers | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Mahlon | Last name of sampler or witnessed by | Lindenmuth |
| Title of sampler | QA Inspector | Telephone number of sampler | 646-740-3704 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CK Johnson | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S46-122-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 107480 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | 0820-553 | Bolt Specification | N/A |
| Bolt Length(s) | Nut Specification | N/A | |
| Washer Specification | ASTM F436 | Finish | ASTM A153 HDG |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-02-09-16
DIME Test ID: 2021-02-09-16-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Test Release Date: 2021-03-02
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 02/23/2021
Sample No.: 1B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 0820-553
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: TSI F436
Size: .625 in
Bolt Length: no data
Hardness Reading Scale: C Scale
Spacing: Ok
Hardness Reading Average: 40.45
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/2/2021 ✔