Summary for Test 2021-02-05-10-3

Test performed: AASHTO T85-13

Project Information

Project IdentifiersProject ID: 215083
DEA: 07307504
EFIS: 0714000217
DIST-CO-RTE-PM07-LA-101-11.8/31.1
Award Date09/21/2020
Closeout Date08/25/2022
Work DescriptionPLACE RHMA-G, MODIFY RAMP METERING AND SIGNAL AND LIGHTING SYSTEMS.
Location DescriptionLOS ANGELES COUNTY FROM TUJUNGA AVENUE UNDERCROSSING TO LAS VIRGENES ROAD OVERCROSSING
QA Service Level1 (Verified on 11/18/2020)

Sample Information

Sample Taken Date02/05/2021 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing02/10/2021 Sample typeVerification
A brief description of the sampleJMF 3/4" HMA-A-SP R15 0.5 % LAS The quantity of what the sample constitutes10 Bags of Aggregate, 1 Bag of RAP
From where was the sample collectedManufacturer First name of sampler or witnessed byVulcan Sun Valley
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification0143A-21
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan - Sun Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035::FISH CANYON QUARRY
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number220831 SVA SJR A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-02-05-10
DIME Test ID: 2021-02-05-10-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Test Release Date: 2021-02-22

Test Results


Basis for relative density testing: Bulk
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 02/17/2021
Mass of sample saturated surface dry aggregate: 3119 grams
Mass of sample in water: 1966 grams
Mass of sample after oven drying: 3081 grams
Specific Gravity: 2.672
Absorption: 1.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/22/2021 ✔