Summary for Test 2021-02-10-1-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 213406 DEA: 030F2504 EFIS: 0300000075 |
|---|---|
| DIST-CO-RTE-PM | 03-YOL,SAC-80-R11.1/R11.7,M0.0/M0.5 |
| Award Date | 08/21/2020 |
| Closeout Date | 07/31/2023 |
| Work Description | SAC RIVER BOH (BRYTE BEND) |
| Location Description | SACRAMENTO AND YOLO COUNTIES IN WEST SACRAMENTO AND SACRAMENTO FROM 0.1 MILE WEST OF REED AVENUE UNDERCROSSING TO 0.1 MILE EAST OF SACRAMENTO RIVER BRIDGE AND OVERHEAD |
| QA Service Level | 1 (Verified on 06/07/2018) |
Sample Information
| Sample Taken Date | 02/10/2021 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/12/2021 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM A325 Bolts |
| The quantity of what the sample constitutes | 5,563 bolts | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Mahlon | Last name of sampler or witnessed by | Lindenmuth |
| Title of sampler | QA Inpector | Telephone number of sampler | 646-740-3704 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CK Johnson | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S46-150-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 443696A |
|---|---|---|---|
| Heat Number(s) | 100205135 | Nut Mfg. Lot Number(s) | N/A |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 2-1/4" | Nut Specification | N/A |
| Washer Specification | N/A | Finish | ASTM F2329 HDG |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | 443696A |
| Rocap Test Requirement(s) | YES | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-02-10-1
DIME Test ID: 2021-02-10-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2021-03-02
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 02/18/2021
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 443696A | 0.6250 | 30757 | 136.82 | 10.00 | A325 Bolt | bewing |
General comments (publicly viewable) (Max 1000 characters): A325 Bolt
Test Graph
Source: Bluehill Data Point FileTest was verified on 3/2/2021 ✔