Summary for Test 2021-02-03-26-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 213819 DEA: 051F8204 EFIS: 0514000064 |
|---|---|
| DIST-CO-RTE-PM | 05-MON-101-R6.7 |
| Award Date | 09/18/2020 |
| Closeout Date | 08/23/2023 |
| Work Description | SAN ANTONIO RIVER BRIDGE-SEISMIC RETROFIT |
| Location Description | MONTEREY COUNTY NEAR BRADLEY AT SAN ANTONIO RIVER BRIDGE |
| QA Service Level | 1 (Verified on 09/30/2019) |
Sample Information
| Sample Taken Date | 02/03/2021 | Sample Unique Key | 26 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/11/2021 | Sample type | Quality Assurance |
| A brief description of the sample | ASTM F1554 Grade 105 All Thread Rod | The quantity of what the sample constitutes | 24 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Ryan |
| Last name of sampler or witnessed by | Parr | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Portland Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | A202592, 201248, 42002150 | Nut Mfg. Lot Number(s) | DECJ |
| Washer Mfg. Lot Number(s) | 0720-522 | Bolt Specification | ASTM F1554 |
| Bolt Length(s) | 5-1/2" | Nut Specification | ASTM A194 |
| Washer Specification | ASTM F436 | Finish | HDG |
| Diameter/Size | 1-1/2" | Bolt Mfg. Lot Number | 1-4375 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2021-02-03-26
DIME Test ID: 2021-02-03-26-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-02-23
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 02/18/2021
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1 | DECJ | 230877 | Nut Proof | bewing |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 2/23/2021 ✔