Summary for Test 2020-09-10-30-7

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 214518
DEA: 034F3704
EFIS: 0314000152
DIST-CO-RTE-PM03-NEV-174-2.7/4.6
Award Date01/24/2020
Closeout Date01/19/2023
Work DescriptionREALIGN ROADWAY CURVES.
Location DescriptionNEVADA COUNTY NEAR PEARDALE FROM MAPLE WAY TO YOU BET ROAD
QA Service Level1 (Verified on 11/22/2019)

Sample Information

Sample Taken Date09/10/2020 Sample Unique Key30
Date that the sample was received by the laboratory/organization performing the testing09/11/2020 Sample typeVerification
A brief description of the sample3/4" HMA - w/RAP The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byBrad McKeehan (WITNESS)
Last name of sampler or witnessed byBrad McKeehan (WITNESS) Title of samplerDSG Personnel
Telephone number of sampler Laboratory sample identificationJMF20-029B
Linked DIME Sample ID The fabricator/manufacturer/facility nameDeSilva Gates Aggregates-Marysville
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-09-10-30
DIME Test ID: 2020-09-10-30-7
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-02-18

Test Results


Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 10/08/2020
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 5.86 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 7.29 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
General comments (publicly viewable) (Max 1000 characters): JMF20-029B.

Test was verified on 2/18/2021 ✔