Summary for Test 2020-01-17-19-10
Test performed: CTM 204-June 2010Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/17/2020 | Sample Unique Key | 19 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2020 |
| Sample type | Quality Control | A brief description of the sample | agg for rock quality |
| The quantity of what the sample constitutes | Multiple bags blended agg | From where was the sample collected | Source |
| First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Miltz |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Salinas Asphalt Facility | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-27-0028::HANDLEY RANCH QUARRY |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Sample taken from hot bins | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-01-17-19
DIME Test ID: 2020-01-17-19-10
Testing Lab: Granite Construction Company - Coastal
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2021-02-11
Test Results
The test method used?: Plastic Index
Input Type: Calculated
Tester's full name: Gwynn Neilson
Date of test: 02/14/2020
Liquid Limit (LL): 1 %
Plastic Limit (PL): 1 %
Plastic Index(PI): 1
General comments (publicly viewable) (Max 1000 characters): Arbitrary numbers filled; aggregate in mix is Non Plastic.
Test was verified on 2/11/2021 ✔