Summary for Test 2020-11-13-20-3
Test performed: AASHTO T308-10
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/13/2020 | Sample Unique Key | 20 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/13/2020 | Sample type | Verification |
| A brief description of the sample | 1/2'' RHMA+10% RAP+WMA | The quantity of what the sample constitutes | 20 boxes |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Mark |
| Last name of sampler or witnessed by | Daniels | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Construction Company | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2020-11-13-20
DIME Test ID: 2020-11-13-20-3
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-02-11
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Frank Chavez Jr
Date of test: 02/03/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1580.0 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1441.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.96 %
Moisture Content: 0.23 %
Temperature Compensation Factor: no data
Test Temperature: 540 F
Corrected Asphalt Binder Content: 7.55 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/11/2021 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.