Summary for Test 2021-02-09-24-3
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 214841 DEA: 034H1004 EFIS: 0318000176 |
---|---|
DIST-CO-RTE-PM | 03-SIE-49-9.2/24.7 |
Award Date | 05/29/2020 |
Closeout Date | 07/29/2022 |
Work Description | INSTALL RETAINING STRUCTURE AND RSP CONCRETE EMBANKMENT. |
Location Description | SIERRA COUNTY ON ROUTE 49 AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 03/24/2020) |
Sample Information
Sample Taken Date | 02/09/2021 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 02/09/2021 |
Sample type | Quality Assurance | A brief description of the sample | #8 HRC 555 |
The quantity of what the sample constitutes | 300 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | Brannon |
Title of sampler | ASI | Telephone number of sampler | 916-826-6371 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Pacific Steel Group | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 3500011782 | Head Manufacturer Lot Number(s) | 1 |
Rebar Size | #8 | Headed Bar Model Name | HRC 555 |
Size of Head | Reduced Size - 4x | Head Connection Type | Friction Weld |
Head Shape | Circular | Rebar Manufacturer | Nucor |
Head Manufacturer | HRC | Head Fabricator | Pacific Steeel Group |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2021-02-09-24
DIME Test ID: 2021-02-09-24-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-02-10
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 02/09/2021
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 0.79 | 32305 | 40893 | Head Broke OFF | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Head Broke OFF
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 2/10/2021 ✔