Summary for Test 2020-11-13-18-4
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/13/2020 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/03/2021 |
Sample type | Verification | A brief description of the sample | Bagged aggreagte - Drum Plant |
The quantity of what the sample constitutes | Bags of aggregate | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Mark | Last name of sampler or witnessed by | Daniels |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 21-JMFPP-0016 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Granite Construction Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-39-0002::VERNALIS |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-11-13-18
DIME Test ID: 2020-11-13-18-4
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2021-02-09
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 02/04/2021
Clay Level (Test 1): 6.1
Sand Level (Test 1): 4
Clay Level (Test 2): 6.1
Sand Level (Test 2): 4.1
Clay Level (Test 3): 6.5
Sand Level (Test 3): 4.2
Sand Equivalent (Test 1): 66
Sand Equivalent (Test 2): 68
Sand Equivalent (Test 3): 65
Sand Equivalent: 67
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/9/2021 ✔