Summary for Test 2020-11-13-18-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/13/2020 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing02/03/2021 Sample typeVerification
A brief description of the sampleBagged aggreagte - Drum Plant The quantity of what the sample constitutesBags of aggregate
From where was the sample collectedSupplier First name of sampler or witnessed byMark
Last name of sampler or witnessed byDaniels Title of sampler
Telephone number of sampler Laboratory sample identification21-JMFPP-0016
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Construction Company
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-39-0002::VERNALIS
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-11-13-18
DIME Test ID: 2020-11-13-18-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-02-09

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 02/08/2021
Cumulative Mass RetainedCumulative Percent Passing
2253.7 grams
grams %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
75.0 grams96.7 %
346.9 grams84.6 %
1452.1 grams35.6 %
370.2 grams19.2 %
536.3 grams11.8 %
629.1 grams7.6 %
687.3 grams5.1 %
728.6 grams3.2 %
749.3 grams2.31 %
grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/9/2021