Summary for Test 2021-02-04-1-1
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 212571 DEA: 051F79A4 EFIS: 0514000061 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-55.9/R56.2 |
| Award Date | 09/13/2022 |
| Closeout Date | Not set |
| Work Description | Nojoqui Creek Bridge (51-0018 L/R) widening and rail replacement. |
| Location Description | IN SANTA BARBARA COUNTY NEAR BUELLTON AT NOJOQUI CREEK BRIDGE (BR #51-0018 L/R) |
| QA Service Level | 1 (Verified on 02/20/2020) |
Sample Information
| Sample Taken Date | 02/04/2021 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/05/2021 |
| Sample type | Quality Assurance | A brief description of the sample | HRC 555 End Anchors |
| The quantity of what the sample constitutes | 24 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
| Title of sampler | QA | Telephone number of sampler | 415-608-1742 |
| Laboratory sample identification | Linked DIME Sample ID | 2021-02-01-1 | |
| The fabricator/manufacturer/facility name | PJ | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-005-21 | Structure unique identifier | |
| Structure name | NOJOQUI Creek Bridge | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4081620 | Head Manufacturer Lot Number(s) | Lot 1 |
| Rebar Size | #9 | Headed Bar Model Name | HRC 555 |
| Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
| Head Shape | Circular | Rebar Manufacturer | CMC |
| Head Manufacturer | PJ | Head Fabricator | PJ |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2021-02-04-1
DIME Test ID: 2021-02-04-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-02-08
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 02/05/2021
UTM: 400kip
Temperature: 72 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 98910 | 98910 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 2/8/2021 ✔