Summary for Test 2020-12-29-3-6
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 12/29/2020 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/29/2020 |
| Sample type | Aggregate Prequalification Program | A brief description of the sample | Washed 1.0" Crushed PCC Aggregate |
| The quantity of what the sample constitutes | 8 Bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Maldonado |
| Title of sampler | Quality Control Tech | Telephone number of sampler | |
| Laboratory sample identification | 2928 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | VULCAN FISH CANYON QUARRY | Transportation Laboratory (TL) Number | C-2020-11-12-21 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0035::FISH CANYON QUARRY |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stckpile | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-12-29-3
DIME Test ID: 2020-12-29-3-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2021-02-02
Test Results
What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Friday Ofoegbu
Date of test: 01/05/2021
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 100 % | ||||||
| 94 % | ||||||
| 78 % | ||||||
| 34 % | ||||||
| 12 % | ||||||
| 2 % | ||||||
| 1 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/2/2021 ✔