Summary for Test 2021-01-06-17-2
Test performed: AASHTO T51-13Project Information
| Project Identifiers | Project ID: 214293 DEA: 060S4604 EFIS: 0615000038 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-99-R0.9/R5.0 |
| Award Date | 12/05/2019 |
| Closeout Date | 05/11/2023 |
| Work Description | REPLACE CONCRETE AND ASPHALT PAVEMENT. |
| Location Description | FRESNO COUNTY IN AND NEAR KINGSBURG AND SELMA FROM ROUTE 99/201 SEPARATION TO 0.3 MILE SOUTH OF SECOND STREET UNDERCROSSING |
| QA Service Level | 1 (Verified on 08/05/2019) |
Sample Information
| Sample Taken Date | 01/06/2021 | Sample Unique Key | 17 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/22/2021 | Sample type | Department Acceptance |
| A brief description of the sample | Project Sample | The quantity of what the sample constitutes | 1 of 5 |
| From where was the sample collected | Source | First name of sampler or witnessed by | G. |
| Last name of sampler or witnessed by | DITT | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CMI FRESNO | |
| Transportation Laboratory (TL) Number | C040295 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-10 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | Not set | |
| Certified Asphalt Supplier | Not set | Multigrade | Not set |
| Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2021-01-06-17
DIME Test ID: 2021-01-06-17-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-01-29
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: Three
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 01/26/2021
Ductility of test #1 (D1): 133 cm
Ductility of test #2 (D2): 142 cm
Ductility of test #3 (D3): 135 cm
Ductility of sample: 137 cm
General comments (publicly viewable) (Max 1000 characters): per 2018 specifications standards
Test was verified on 1/29/2021 ✔