Summary for Test 2021-01-19-7-4
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 214227 DEA: 100Q1214 EFIS: 1014000167 |
|---|---|
| DIST-CO-RTE-PM | 10-MER-99-28.2/R37.3 |
| Award Date | 12/04/2019 |
| Closeout Date | 12/05/2022 |
| Work Description | PLACE REINFORCED CONCRETE PAVEMENT, HMA & FIBER OPTIC CABLE SYSTEM. |
| Location Description | MERCED COUNTY IN AND NEAR LIVINGSTON FROM 0.8 MILE SOUTH OF HAMMATT AVENUE OVERCROSSING TO STANISLAUS COUNTY LINE |
| QA Service Level | 1 (Verified on 06/26/2019) |
Sample Information
| Sample Taken Date | 01/19/2021 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/26/2021 | Sample type | Authorization |
| A brief description of the sample | Headed Bars | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Dante |
| Last name of sampler or witnessed by | Trujillo | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | HRC | |
| Transportation Laboratory (TL) Number | C502 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Rebar Heat Number(s) | NA | Head Manufacturer Lot Number(s) | 10 18 11 18 |
| Rebar Size | #10 | Headed Bar Model Name | 670 |
| Size of Head | Reduced Size - 4x | Head Connection Type | Threaded |
| Head Shape | Circular | Rebar Manufacturer | NA |
| Head Manufacturer | HRC | Head Fabricator | HRC |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2021-01-19-7
DIME Test ID: 2021-01-19-7-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-01-26
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 01/26/2021
UTM: 400kip
Temperature: 72 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 1.27 | 120926 | 95218 | Head Pull off | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Head Pull off
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 1/26/2021 ✔