Summary for Test 2020-04-15-43-7
Test performed: CTM 206-October 2011Project Information
| Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/15/2020 | Sample Unique Key | 43 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/14/2020 | Sample type | Aggregate Prequalification Program |
| A brief description of the sample | 1.5" PCC Aggregate | The quantity of what the sample constitutes | 10 Bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Mike |
| Last name of sampler or witnessed by | Davila | Title of sampler | Hanson QC |
| Telephone number of sampler | 626-856-6720 | Laboratory sample identification | 2809 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Lehigh Hanson | |
| Transportation Laboratory (TL) Number | None | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0025::IRWINDALE |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | From the source | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1-1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-04-15-43
DIME Test ID: 2020-04-15-43-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse Aggregate
Test Release Date: 2021-01-25
Test Results
How will the aggregate be used?: portland cement
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 12/17/2020
% Water Absorbed: 0.8 %
Bulk Saturated Surface Dry Specific Gravity: 2.60
General comments (publicly viewable) (Max 1000 characters): App=2.66
SSD=2.63
OD=2.60
Test was verified on 1/25/2021 ✔