Summary for Test 2020-12-22-10-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date12/22/2020 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing01/06/2021 Sample typeVerification
A brief description of the sampleBoxes of HMA-A The quantity of what the sample constitutesOne JMFPP Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byC.
Last name of sampler or witnessed byBrown Title of sampler
Telephone number of sampler Laboratory sample identificationD5 21-J-002
Linked DIME Sample ID The fabricator/manufacturer/facility nameSyar Lake Herman
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-12-22-10
DIME Test ID: 2020-12-22-10-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-01-22

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: E. Atkins
Date of test: 01/21/2021
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1691.0 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 2.16 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 900 F
Corrected Asphalt Binder Content: 5.78 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/22/2021