Summary for Test 2020-12-22-11-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 12/22/2020 | Sample Unique Key | 11 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/06/2021 | Sample type | Verification |
| A brief description of the sample | Bag of RAP | The quantity of what the sample constitutes | One JMFPP Verification |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | C. |
| Last name of sampler or witnessed by | Brown | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Syar Lake Herman | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Lake Herman Stockpile |
|---|---|---|---|
| Aggregate Size | Fine RAP | Aggregate Source | |
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2020-12-22-11
DIME Test ID: 2020-12-22-11-2
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-01-22
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 01/13/2021
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1779.3 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 3.41 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 4.25 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/22/2021 ✔