Summary for Test 2020-12-22-9-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/22/2020 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/06/2021 |
Sample type | Verification | A brief description of the sample | Bags of Aggregate |
The quantity of what the sample constitutes | One JMFPP Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | C. | Last name of sampler or witnessed by | Brown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D5 21-J-002 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Syar Lake Herman | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-48-0002::LAKE HERMAN QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | At the Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-12-22-9
DIME Test ID: 2020-12-22-9-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-01-22
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 01/26/2021
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 97.9 %
Cumulative percent passing the 3/8 in. sieve: 84.7 %
Cumulative percent passing the #4 sieve: 60.5 %
Cumulative percent passing the #8 sieve: 39.9 %
Cumulative percent passing the #16 sieve: 26.3 %
Cumulative percent passing the #30 sieve: 18.3 %
Cumulative percent passing the #50 sieve: 12.9 %
Cumulative percent passing the #100 sieve: 8.5 %
Cumulative percent passing the #200 sieve: 5.6 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/22/2021 ✔