Summary for Test 2021-01-14-7-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214227
DEA: 100Q1214
EFIS: 1014000167
DIST-CO-RTE-PM10-MER-99-28.2/R37.3
Award Date12/04/2019
Closeout Date12/05/2022
Work DescriptionPLACE REINFORCED CONCRETE PAVEMENT, HMA & FIBER OPTIC CABLE SYSTEM.
Location DescriptionMERCED COUNTY IN AND NEAR LIVINGSTON FROM 0.8 MILE SOUTH OF HAMMATT AVENUE OVERCROSSING TO STANISLAUS COUNTY LINE
QA Service Level1 (Verified on 06/26/2019)

Sample Information

Sample Taken Date01/14/2021 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing01/15/2021 Sample typeQuality Assurance
A brief description of the sampleBar Lock Coupler The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byJO
Last name of sampler or witnessed byAkabogn Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Rebar Erico
Transportation Laboratory (TL) NumberC10Q1214QA Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerErico Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelBar Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)C0026 Rebar Heat Number(s)4102989
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-01-14-7
DIME Test ID: 2021-01-14-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-01-19

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 01/19/2021
UTM: 2000kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 11/36mm101.5614759194609Service Splicefsaylor

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 1/19/2021 ✔