Summary for Test 2020-12-22-8-6
Test performed: AASHTO T313-19Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/22/2020 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/08/2021 |
Sample type | Verification | A brief description of the sample | Asphalt Binder |
The quantity of what the sample constitutes | 5 cans, 1 can per week | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Gustavo | Last name of sampler or witnessed by | Moreno |
Title of sampler | COC Program | Telephone number of sampler | 562-928-7000 |
Laboratory sample identification | 122220-054 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | WORLD OIL | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | 1234 | |
Time of sample | 12:30am | HMA Supplier | Not set |
Certified Asphalt Supplier | Not set | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-12-22-8
DIME Test ID: 2020-12-22-8-6
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2021-01-13
Test Results
Input Type: Measured
Tester's full name: Harish Thaur
Date of test: 01/13/2021
Minimum test bath temperature at 240 s: -12.0 C
Maximum test bath temperature at 240 s: -12.0 C
Time of test load application: no data
File name of test data: no data
Time beam in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficient (R²): 0
Regression coefficient a: no data
Regression coefficient b: no data
Regression coefficient c: no data
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Load at 60.0 s: 0.0 mN
Beam deflection 60.0 s: 0.000 µm
Measured Stiffness Modulus 60.0 s: 87.900 mPa
Estimated Stiffness Modulus 60.0 s: no data
Difference between stiffness moduli 60.0 s: no data
Estimated m-value 60.0 s: 0.312
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 1/13/2021 ✔