Summary for Test 2020-12-30-9-4
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 214702 DEA: 030F2864 EFIS: 0320000123 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99-7.92 / 8.4 |
Award Date | 06/24/2020 |
Closeout Date | 11/28/2023 |
Work Description | Remove and replace Consumnes River and Consumnes River Overflow bridge |
Location Description | Sacramento County |
QA Service Level | 1 (Verified on 04/20/2020) |
Sample Information
Sample Taken Date | 12/30/2020 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/07/2021 |
Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
The quantity of what the sample constitutes | 61 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | ||
Group Number | 10961 | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0569320-2, S0569120-2, S0569720-3, S0514120-2, S0525620, S0568320, S0218590, S0216056, S0218045, S0559420-2, S0514420-2, S0513920-2, S0514320-2 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2020-12-30-9
DIME Test ID: 2020-12-30-9-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-01-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 01/07/2021
UTM: 120kip
Temperature: 72 f
Extensometers: no data
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0569720-3 | S379433-2 | 0.214 | 59588 | 54828.7 | 27.4 | 1.67 | bewing |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 1/12/2021 ✔