Summary for Test 2015-05-01-3-2
Test performed: CTM 521-November 2014Project Information
| Project Identifiers | Project ID: 209948 DEA: 072055A4 EFIS: 0714000277 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-2-14.1/14.8 |
| Award Date | 01/09/2015 |
| Closeout Date | 08/24/2017 |
| Work Description | CONSTRUCT SOUNDWALLS, CURB RAMPS AND SIDEWALK. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF GLENDALE BOULEVARD UNDERCROSSING TO ROSEBUD AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 07/07/2015) |
Sample Information
| Sample Taken Date | 05/01/2015 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/08/2015 |
| Sample type | Quality Control | A brief description of the sample | 6x12 |
| The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | MARK | Last name of sampler or witnessed by | AMORSOLO |
| Title of sampler | Structure Rep | Telephone number of sampler | Unknown |
| Laboratory sample identification | 905-58 | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | JOB | Transportation Laboratory (TL) Number | 0024958 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | NB GLENDALE RTE 2 SOUND WALL |
| Structure name | NB GLENDALE RTE2 SOUND WALL | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 557237SP |
|---|---|---|---|
| The truck number from where the sample was collected | NOT PROVIDED | The batch plant ticket number from where the sample was collected | NOT PROVIDED |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | Not set |
| From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-05-01-3
DIME Test ID: 2015-05-01-3-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-05-15
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 05/15/2015
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 118150 lb
Maximum load on cylinder 2: 117420 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 14 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength of cylinder 1: 4179.3 psi
Compressive strength of cylinder 2: 4166.8 psi
Compressive strength (to nearest 10 psi): 4170 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/15/2015 ✔